Line 143: | Line 143: | ||
<div class="mainbody"> | <div class="mainbody"> | ||
− | + | After the further discussion with several professiors, we found that the first-generation device was not efficient in fluorescence excitation, and some details were unreasonable ,it can not meet the requirements and cost of 3D printing technology. But the second-generation device optimized the optical path based on the first-generation device and need no more transparent parts. The measuement angle was fixed at 45° angle to enhance fluorescence excitation efficiency. | |
</div> | </div> | ||
Revision as of 14:28, 21 October 2019
Overview
In order to achieve the application of our engineered bactria in practise, we designed the expired drugs recycling and degrading device (Drug Avenger) and the fluorescence detection device.
Expired drugs recycling and degrading device (Drug Avenger) was used to recycle expired drugs. The modular design allowed for the recovery of three types of drugs. Fig. 2. and animation show the design and theoretical ideas.
Fig. 1. Expired drugs recycling and degrading device named Drug Avenger
Fig. 2. Print of the function module
Fig. 3. The fluorescence detection device
Device iteration
In the development process of hardware, our detection device module had been updated three iderations, and finally the third generation version was designed and realized.
First generation device
Fig. 4. Light path of the first generation device
Second generation device
Fig. 5. Light path of the second generation device
Third generation device
Fig. 6. The funnel-shaped groove of the third generation device
please click on the two buttons below.
Input | Output | Size | Wavelength | Chip | Power | Aperture | Cut-On Wavelength | focal length | diameter | ADC | |
---|---|---|---|---|---|---|---|---|---|---|---|
Photodetector | Silicon-based avalanche diode | 200~1000nm | |||||||||
Laser | 450nm | 4.8mw | |||||||||
Development board | 12V | STM32F103C8T6 | ADS1256 | ||||||||
Relay | 12V | Four-way optocoupler isolation | |||||||||
Water pump | 5V | ||||||||||
Filter membrane | 0.22μm | ||||||||||
Switching power supply | 220V/110V | 12V/5V | |||||||||
optical filter | 500nm | ||||||||||
Convex lens | 25mm | 1 inch |
Expectation
designing other drug degradation modules. We have reserved some modular designs to make them much easier and more convenient to implement. We also hope to optimize the design detection module. By doing so, we can get more stable and efficient signals and implementate the device at a lower cost.