Difference between revisions of "Team:UESTC-China/Hardware"

Line 88: Line 88:
 
</div>
 
</div>
 
<div class="words" >
 
<div class="words" >
<p>Fig. 1.  Expired drugs recycling and degrading device, which we call it Drug Avenger</p>
+
<p>Fig. 1.  Expired drugs recycling and degrading device named Drug Avenger</p>
 
</div>
 
</div>
 
 
Line 106: Line 106:
 
   
 
   
 
  <div class="mainbody">
 
  <div class="mainbody">
  The fluorescence detection device was used to specifically detect the CIP concentration, and was assembled by a switching power supply, water pumps, capture card, photodetector, and an external device.
+
  In this project,the fluorescence detection device was used to specifically detect the CIP concentration, and it was assembled by a switching power supply, water pumps, capture card, photodetector, and an external device.
 
  </div>
 
  </div>
 
   
 
   

Revision as of 14:18, 21 October 2019

description

logo

Overview

In order to achieve the application of our engineered bactria in practise, we designed the expired drugs recycling and degrading device(Drug Avenger) and the fluorescence detection device.

Expired drugs recycling and degrading device(Drug Avenger) was used to recycle expired drugs. The modular design allowed for the recovery of three types of drugs. Fig. 2. and animation show the design and theoretical ideas.

logo

Fig. 1. Expired drugs recycling and degrading device named Drug Avenger

logo

Fig. 2. Print of the function module

In this project,the fluorescence detection device was used to specifically detect the CIP concentration, and it was assembled by a switching power supply, water pumps, capture card, photodetector, and an external device.
logo

Fig. 3. The fluorescence detection device

Device iteration

In the development process of hardware, our detection device module had been updated three iderations, and finally the third generation version was designed and realized.

logoFirst generation device

The first generation of detection modules consists of photodetectors, laser sources, STM32 Development board, pumps, filters, lenses, and external devices with an optical path of 90°.
logo

Fig. 4. Light path of the first generation device

logoSecond generation device

During the further discussion with several professiors, we found that the first-generation device was not efficient in fluorescence excitation, and some details were unreasonable because of the requirements and cost of 3D printing technology. But the second-generation device optimized the optical path based on the first-generation device and need no more transparent parts. A new optical path of 45° angle was used to enhance fluorescence excitation efficiency.
logo

Fig. 5. Light path of the second generation device

logoThird generation device

We tried the second generation device and found that it was not stable enough to detect the weak fluorescence. Under the guidance of Dr.Gul, we fixed the shortcomings of the original device in the fixation of the engineering bacteria, and designed the funnel-shaped groove, which was conducive to the accumulation of engineering bacteria and also improve the stability of the detection fluorescent signal.
logo

Fig. 6. The funnel-shaped groove of the third generation device

Finally, we designed a community drug recycling bin and fluorescence detection device based on the third generation of detection module devices. For more detailed information on the design of community drug recycling bins and fluorescence detection devices,

please click on the two buttons below.

Expired drugs recycling and degrading device
Fluorescence detection devices
Open source
In order to make other teams understand it easily and improve hardware together, we share important parameters, 3D models and acquisition software below.
Parameters
Input Output Size Wavelength Chip Power Aperture Cut-On Wavelength focal length diameter ADC
Photodetector Silicon-based avalanche diode 200~1000nm
Laser 450nm 4.8mw
Development board 12V STM32F103C8T6 ADS1256
Relay 12V Four-way optocoupler isolation
Water pump 5V
Filter membrane 0.22μm
Switching power supply 220V/110V 12V/5V
optical filter 500nm
Convex lens 25mm 1 inch

Expectation

designing other drug degradation modules. We have reserved some modular designs to make them much easier and more convenient to implement. We also hope to optimize the design detection module. By doing so, we can get more stable and efficient signals and implementate the device at a lower cost.