Difference between revisions of "Team:Marburg/Measurement"

Line 239: Line 239:
 
         </div>
 
         </div>
 
       </div>
 
       </div>
       <div class="sub" onclick="popup('rbn3')">
+
       <div class="sub" onclick="popup('facs')">
 
         <div class="sub-header">
 
         <div class="sub-header">
 
           <h1>
 
           <h1>
Line 252: Line 252:
 
         </div>
 
         </div>
 
       </div>
 
       </div>
       <div id="rbn3" class="popup">
+
       <div id="facs" class="popup">
 
         <div class="popup-container">
 
         <div class="popup-container">
 
           <div class="popup-header">
 
           <div class="popup-header">
 
             <h1 class="title">Fluorescence-Activated Cell Sorting (FACS)</h1>
 
             <h1 class="title">Fluorescence-Activated Cell Sorting (FACS)</h1>
             <button type="button" onclick="hide('rbn3')">X</button>
+
             <button type="button" onclick="hide('facs')">X</button>
 
           </div>
 
           </div>
 
           <div class="popup-content">
 
           <div class="popup-content">
 
             <div>
 
             <div>
 
             <p>
 
             <p>
               Fluorescence Activated Cell Sorting (FACS) is a flow cytometry measurement technique that separates single cells with different fluorescence characteristics. In this method you get accurate measuring results, because every single cell is analyzed on its own. FACS analysis can be used for cell sorting, fluorescence analysis of single cells and cell counting of different sample mixtures.<br>
+
        <p style="text-align: justify; margin-bottom: 1em;">
               In flow cytometry, the sample with the cells get hydrodynamically focused in a single stream. The cells arrange in a row, so that they can pass a laser one by one. The cells get excited by the laser and emit light at various wavelengths, which is then detected by a fluorescence analysator. The detector can detect and separate different fluorescence intensities at a definite range of wavelengths. Through this cells can be categorized by different fluorescent characteristics and if wanted separated into defined categories by a deflection system using electromagnetic fields. <br>
+
               Fluorescence Activated Cell Sorting (FACS) is a flow cytometry measurement technique that separates single cells with different fluorescence characteristics. In this method you get accurate measuring results, because every single cell is analyzed on its own. FACS analysis can be used for cell sorting, fluorescence analysis of single cells and cell counting of different sample mixtures.
 +
        <p style="text-align: justify; margin-bottom: 1em;">
 +
 
 +
               In flow cytometry, the sample with the cells get hydrodynamically focused in a single stream. The cells arrange in a row, so that they can pass a laser one by one. The cells get excited by the laser and emit light at various wavelengths, which is then detected by a fluorescence analysator. The detector can detect and separate different fluorescence intensities at a definite range of wavelengths. Through this cells can be categorized by different fluorescent characteristics and if wanted separated into defined categories by a deflection system using electromagnetic fields.  
 +
        <p style="text-align: justify; margin-bottom: 1em;">
 +
 
 
               Furthermore, it is possible to determine the cell volume and size, as well as to distinguish between different kinds of cells, particles or cell clumps. For this, there are scatter detectors around the capilar. A forward scatter detector (FSC) and a stream side scatter detector (SSC) are placed around the stream.<br><br>
 
               Furthermore, it is possible to determine the cell volume and size, as well as to distinguish between different kinds of cells, particles or cell clumps. For this, there are scatter detectors around the capilar. A forward scatter detector (FSC) and a stream side scatter detector (SSC) are placed around the stream.<br><br>
 
             </p>  
 
             </p>  

Revision as of 14:32, 7 December 2019

M E A S U R E M E N T


Amplifying new standards in measurement

We entered this project as the first Marburg iGEM team working with Synechococcus elongatus UTEX 2973, the fastest phototrophic organism. Missing knowledge in handling and cultivation of UTEX 2973 left us in front of many problems and questions. Especially the usage of different media, light conditions and other cultivating and measurement parameters were one of the biggest problems we discovered in scientific papers. Many of these problems are reasoned in the ongoing optimization and development of methods and instruments. Therefore it is hard to hold on to special methods; nevertheless, standardization is paramount in synthetic microbiology in order to be able to compare results with other scientists and reproduce their data.

Because we wanted to establish Synechococcus elongatus as a new chassis for the iGEM community and scientists, we should show the best conditions for cultivation and the best measuring method for our parts in UTEX 2973. Therefore we analyzed a big variety of cultivating conditions in measuring growth curves, tried to find a standard in light measurement, evaluated different reporters, established a measurement method and compared it to a already known FACS measurement method.

At the beginning of our project we faced the first question: how to cultivate UTEX at 1500 μE? To answer this we had to measure the light conditions in our incubators and while doing this simple task the first part of standardization began. We discovered that nearly every paper is using different methods to measure their light conditions and that it is a really complex and important procedure. So we got in contact with Cyano and light measurement experts to confront this problem and standardize it. In the following popups we show different ways of measurement, their (dis-)advantages and different results depending on the measuring instrument.

Moreover, not only the light intensity but also a variety of other cultivating parameters needed to be analyzed. In literature and while talking with different experts, we recognized that small deviations of these parameters had a huge impact on the growth speed of Synechococcus elongatus. While establishing UTEX 2973 as a new chassis we evaluated this impact on the growth speed and were able to show combinations of parameters that lead to the fastest growth speed.

Another aspect was measuring the expression and characterize our part. Different possibilities were discussed and after testing them we decided on two methods in our project. One approach was to measure the fluorescence/luminescence with a plate reader. Plate readers belong to standard equipment of every lab nowadays, and could deliver easy reproducible results. The second way was to measure the fluorescence by FACS (Fluorescence-Activated Cell Sorting). In contrast to a platerader a FACs device delivers results with high accuracy by measuring every cell by its own.

However, not every laboratory posses a FACS/device. So in the end we would like to offer a database - analyzed using these two methods - from our constructs for iGEM teams and research groups, who do not have access to a FACS and show the difference in measurement methods.
At the end of the project we were able to create a protocol how to handle Synechococcus elongatus UTEX 2973 and make a contribution to the cyano community by establishing essential/fixed standards in measurements.


L I G H T
M E A S U R E M E N T


Light measurements are a crucial aspect when working on phototrophic organisms - here’s how we tackled some issues we faced!

R E P O R T E R S


Fluorescence Reporters

F A C S


FACS Measurements

P A R T
M E A S U R E M E N T


Establishing a measurement workflow that is not only applicable to UTEX 2973 and other cyanobacteria with a high throughput.

G R O W T H
C U R V E S


Varying our growth conditions we were finally able to achieve doubling times of under 80 minutes.