Team:US AFRL CarrollHS/Contribution

“Image”
“Image”
Contribution_Header_Final
Contribution_Header_Mobile

Bronze Medal Criterion

To fulfill the Measurement criterion, we decided to measure one of our past team’s composite parts from 2017, PLas_sfGFP Part BBa_K2522001 which produces sfGFP in the presence of N-3-oxododecanoyl homoserine lactone (3OC12). Prior to measuring our part, we had to create our standard curves using the iGEM Measurement Plate Reader protocol which are graphed below.

We created six overnights that contained 3 mL of LB Broth, 3 μL of the antibiotic Chloramphenicol, E. coli DH5α cells transformed with PLas_sfGFP, and either 3 μL of 10 mM 3OC12 (three overnights) or 3 μL of DMSO (three overnights) to confirm the functionality of the plasmid and one 3 mL overnight that contained only LB Broth to serve as our blank.

''

Through these overnights, we were able to confirm the functionality of PLas_sfGFP and we measured the fluorescence and absorbance of each overnight by performing an endpoint read of each overnight in a 96-well flat-bottomed plate. In order to obtain data in the range of our standard curve, we diluted the overnights two-fold by mixing 50 μL of each overnight with 50 μL of LB.

We then used the 100 μL Standard Curve we created using the iGEM Measurement Protocols and converted our data from arbitrary absorbance and fluorescence units to MEFL/particle, which we graphed below: 

 Fluorescence (MEFL/Particle)

With 3OC12 (final concentration 10 μM)

With DMSO

  1290000.00

  7810.00

  1310000.00

  1580.00

  1270000.00

  8140.00

 

Since we were able to confirm the functionality of the PLas_sfGFP circuit, we also decided to create a Dose Response Curve for PLas_sfGFP by making overnight triplicates of the PLas_sfGFP induced at different concentrations of 3OC12. 

First, we performed serial dilutions of the 10 mM stock solution of 3OC12 with DMSO. Then, we created overnight in triplicate of cells transformed with PLas_sfGFP that were induced by the different 3OC12 concentrations. Afterward, we diluted and measured the fluorescence and absorbance of each overnight as explained above. Using our 100 μL Standard Curve, we converted our raw measurements and graphed them below:

 Fluorescence (MEFL/Particle)

 

Final Concentration (μM)

Triplicate #1

Triplicate #2

Triplicate #3

5

1581451

1501519

1605886

1

1564336

1418952

1550982

0.5

1612388

1396958

1600123

0.1

1421045

1461045

1416788

0.05

1389708

1407451

1417182

0.01

1289253

1275768

1222314

0.005

1108580

1006372

1255536

0.001

642864

563153

734513

0.0005

362993

348382

305982

0.0001

101434

108762

98193

0.00005

58325

63723

68752

0

32018

34156

32305

The circuit responded to 3OC12 in a dose-dependent manner. We began seeing signal at 10-4 μM and the signal saturated at 10-1 μM. The sensor showed a 60-fold increase in signal upon activation based on the non-linear fit analysis. Analysis was done on GraphPad Prism 5.

We have submitted this characterization in order to fulfill our Bronze Medal Criterion, although we have also used these measurement protocols for the remainder of our experiments. However, our standard curves differ based on factors such as volume and plate type. We’ve graphed all of the other standard curves below.